Plots and Figures for EXO Collaborators
-
EXO Materials Summary. Updated (7/2/2008)
-
EXO Radon Summary. Updated (3/20/2007)
-
EXO Materials Background Impact Summary. Updated (8/12/2004)
-
40K, 232Th and 238U concentrations determined
by counting from various salt samples collected at WIPP (7/2001). Updated (5/2003)
-
Memo on neutron capture cross sections. 4/18/2001
-
NAA of quartz samples. 3/15/2002
-
NAA of Si screw. 6/22/2002
-
NAA results for 3M cryogenic fluid HFE-7100. 12/11/2002
-
NAA results for three integrated circuit chips, provided by SLAC. 12/11/2002
-
Counting results for Macor insulators, machined at UA. 12/11/2002
-
Counting results for 3 APDs. 2/26/2003
-
Monte Carlo background estimate for the 200 kg prototype detector. 4/19/2003
-
Counting results for two 100 g samples of Swedish Boliden
and 200 year old British Pb. 5/9/2003
-
Activation analysis of several Pb samples (Boliden, Cominco), p-terphenyl
and one APD. 5/9/2003
-
Analysis of EXO plastic samples. Candidates for TPC body.
6/25/2003
-
Analysis of raw un-sintered EXO Teflon samples. Candidates for TPC body.
11/5/2003
-
Analysis of one Advanced Photonix Avalanche Photo Diode.
12/20/2003
-
Th purity requirements for a two layer Pb shield. 1/9/2004
-
Polycarbonate samples from Dow Corning, General Electric and Bayer
(obtained through SLAC). Candidates for TPC body.
2/9/2004
-
Calculation of muon induced background in 200 kg
prototype at WIPP depth. 3/19/2004
-
Calculation of cosmogenic production of radio nuclides
in EXO copper. 3/19/2004
Revised version. 60Co number of simulated events
corrected. No change in conclusions. 3/25/2004.
-
Calculated allowed and forbidden beta spectra of 39Ar,
85Kr and 210Bi. 5/11/2004
-
Neutron Activation Analysis of finished Saint Gobain Teflon samples.
5/12/2004
-
Neutron Activation Analysis of 3M cryogenic fluids HFE-7000, HFE-7100,
and FC-87.
6/9/2004
-
Updated calculation of cosmogenic production of radio nuclides
in EXO copper using a realistic exposure scenario. 8/12/2004
-
Neutron Activation Analysis of finished Saint Gobain Teflon samples
produced 6/14/2004 in the presence of A.P.
8/31/2004
-
Background due to Radon trapped in Pb shield. 9/17/2004
-
High sensitivity Neutron Activation Analysis of finished Saint Gobain Teflon samples
produced 6/14/2004 in the presence of A.P.
10/28/2004
-
Activation analysis of 2 Aluminum contacted productions APDs (made by Advanced
Photonix) and their
components. 12/18/2004
-
Monte Carlo calculation of gamma leakage through gaps in lead shield,
background contribution of 222Rn in shielding gaps,
and impact of 210Pb attached to TPC surfaces. 12/21/2004
-
Monte Carlo based comparison of the background due to
a Copper versus a Teflon TPC. 2/20/2005
-
Calibration of scintillator K, Th, and U spikes, calibration
of reactor neutron flux. 8/8/2005
-
Analysis of K, Th, U in evaporated HFE after spiking with liquid
scintillator. 8/8/2005
-
Analysis of pre-concentrated HFE. 8/8/2005
-
MC estimate of background impact of flat Espanex TPC cables.
8/9/2005
-
NAA results for Daikin Teflon and Dynasil Quartz. 8/16/2005
-
NAA of DuPont Teflon TE-6472, Lot: 506830001. Reserved for
EXO. 9/30/2005
-
Monte Carlo background estimate of Teflon top hat TPC. 10/27/2005
-
Monte Carlo estimate of radiopurity requirements for lead clear Epoxy. 11/14/2005
-
Monte Carlo background estimate of Teflon conical weld TPC. 11/15/2005
-
Monte Carlo background estimate of thin walled Copper TPC. 11/18/2005
-
Options for testing of surface cleanliness of Wessington dewar 1/17/2006
-
NAA results for Kapton, Sapphire and Corning Quartz 2/26/2006
-
NAA results for HFE exposed to Wessington dewar 5/8/2006
-
Background contribution of radioactive noble gases in HFE-7000 5/30/2006
-
NAA results for various epoxies and closed cell PE foam 6/4/2006
-
NAA Report: Vespel, Acrylic, Si wafer 8/26/2006
-
NAA Report: APD Al, cryostat Teflon, HV cable insulator 12/22/2006
Back to Andreas' Home Page